Motor Management Parameters

Within this submenu all motor management related parameters can be configured.
The diagram below shows the organisation of the different parameter masks in the menu tree.
The parameters are described in details in the section "Parameters and Data Structures on a Fieldbus->Parameter
Organisation-> Motor Management Parameters". A description of the parameters of the menu entry "Auxiliary
inputs" can be found in the section "Parameters and Data-Structures on a Fieldbus->Parameter Organization->
Function Block Related Parameters".
1
Motor Management
1.1
Control function
1.2
Reverse lockout time
1.3
YD changeover mode
1.4
YD starting time
2
1.5
Time limit actuator
3
1.6
Fault output
1.7
Checkback
1.8
Inching DI start input
1.9
Local ctrl mode 1
1.10
Auto ctrl mode
1.11
Local ctrl mode 2
1.12
Invert ctrl inputs
1.13
Multifunction inputs
1.14
Enable custom logic
1.15
Limit number of starts
1.16
Extended
1.17
Resisitive load
1.18
Number of phases
1.19
Warnlevel oper.hours
1.20
Warnlev standstill h
1) Only for control function REV
2) Only for control function YD
3) Only for control function Actuator
1.9
Local control mode 1
1.9.1
Loc1 start bus cyc.
1
1.9.2
Loc1 stop bus cyc.
2
1.9.3
Loc1 start LCD
1.9.4
Loc1 stop LCD
1.9.5
Loc1 start bus acyc.
1.9.6
Loc1 stop bus acyc.
1.9.7
Loc1 start DI
1.9.8
Loc1 stop DI
1.10
Auto ctrl mode
1.10.1
Auto start bus cyc.
1.10.2
Auto stop bus cyc.
1.10.3
Auto start LCD
1.10.4
Auto stop LCD
1.10.5
Auto start bus acyc.
1.10.6
Auto stop bus acyc.
1.10.7
Auto start DI
1.10.8
Auto stop DI
1.16
Extended
1.16.1
Emergency start
1.16.2
Fault auto reset
1.16.3
Custom app parameter
1.16.4
Param to PV 1
...
1.16.8
Param to PV5
1.16.9
Check-Back Time
1.16.10
Auxiliary inputs
1.16.10
Auxiliary inputs
1.16.5.1
Aux inp 1 ack mode
1.16.5.2
Aux inp 1 reaction
1.16.5.3
Aux inp 1 delay
1.16.5.4
Aux inp 1 message L1
1.16.5.5
Aux inp 1 message L2
...
(Same repeats for Aux
2 ... 6)
1.11
Local control mode 2
1.11.1
Loc2 start bus cyc.
1.11.2
Loc2 stop bus cyc.
1.11.3
Loc2 start LCD
1.11.4
Loc2 stop LCD
1.11.5
Loc2 start bus acyc.
1.11.6
Loc2 stop bus acyc.
1.11.7
Loc2 start DI
1.11.8
Loc2 stop DI
1.13
Multifunction inputs
1.13.1
Multifunction 0
1.13.2
Multifunction 1
1.13.3
Multifunction 2
1.13.4
Multif. 0 delay
1.13.5
Multif. 1 delay
1.13.6
Multif. 2 delay
1.13.7
Multif. 0 autoreset
1.13.8
Multif. 1 autoreset
1.13.9
Multif. 2 autoreset
1.13.10
Multif. 0 fault text L1/2
1.13.12
Multif. 1 fault text L1/2
1.13.14
Multif. 2 fault text L1/2
1.12
Invert ctrl inputs
1.12.1
Invert DI start inp.
1.12.2
Invert DI stop inp.
1.15
Limit num of starts
1.15.1
Num starts allowed
1.15.2
Num starts window
1.15.3
Num starts pause
1.15.4
Num starts overrun
1.15.5
Num starts prewarn