Mitsubishi Electric MELSEC-Q QD75M User Manual page 356

Positioning module
Table of Contents

Advertisement

8 OPR CONTROL
Near-point dog OFF
Zero signal
Fig. 8.13 Count method 1) machine OPR on the near-point dog ON position
Precautions during operation
(1) An error "Count method movement amount fault (error code: 206)" will occur
and the operation will not start if the "
amount after near-point dog ON" is smaller than the deceleration distance
Pr.46
from the "
A deceleration stop will be carried out if the speed is changed during the
operation and an error occurs.
(2) The following shows the operation when a machine OPR is started while the
near-point dog is ON.
(3) When the stop signal stops the machine OPR, carry out the machine OPR
again. When restart command is turned ON after the stop signal stops the
OPR, the error "OPR restart impossible (error code: 209)" will occur.
(4) After the servo amplifier turned on, the zero point of the encoder must be
passed at least once before point A is reached.
Pr. 50 Setting for the movement
amount after near-point dog ON
4)
1)
3)
2)
ON
Pr.47
OPR speed" to "
[Operation when a machine OPR is started at
the near-point dog ON position]
5)
1) A
2) The machine moves at the OPR speed in the
opposite direction of an OPR.
3) Deceleration processing is carried out by
"
selection" when the near-point dog OFF is
detected.
4) After the
is carried out in the OPR direction.
5) The machine OPR is completed after the
deviation counter clear output is provided on
detection of the first zero signal after the
travel of the movement amount set to
"
after near-point dog ON" on detection of the
near-point dog signal ON.
8 - 9
Pr.50
Setting for the movement
Creep speed".
machine
OPR is started.
Pr.39
Stop group 3 sudden stop
machine stops, a machine OPR
Pr.50
Setting for the movement amount
MELSEC-Q

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents