7 MEMORY CONFIGURATION AND DATA PROCESS
(10) Transmitting servo parameter from the buffer memory area to
servo amplifier (
The servo parameter in the buffer memory area is transmitted to the servo
amplifier by the following timing.
1) The servo parameter transmitted to the servo amplifier when communications
with servo amplifier start.
The servo parameter in the buffer memory area is transmitted to the servo
amplifier.
2) The following servo parameter in the buffer memory area carried out to the
servo amplifier when the PLC READY signal [Y0] turns from OFF to ON.
Pr.108
Auto tuning (Servo basic parameter)
Pr.112
Load inertia ratio (Servo adjustment parameter)
Pr.113
Position loop gain 1 (Servo adjustment parameter)
Pr.115
Position loop gain 2 (Servo adjustment parameter)
Pr.114
Speed loop gain 1 (Servo adjustment parameter)
Pr.116
Speed loop gain 2 (Servo adjustment parameter)
Pr.117
Speed integral compensation (Servo adjustment parameter)
Pr.119
Feed forward gain (Servo adjustment parameter)
About the communication start with servo amplifier
Communication with servo amplifier is valid when following condition is realized
together.
1) The power of QD75 and servo amplifier is turned ON.
2) When the motor capacity of servo parameter
area is set to the value other than "0" in QD75.
When the power is turned ON or the PLC CPU is reset, the data stored in the
flash ROM is transmitted to the buffer memory.
Therefore the motor capacity of servo parameter
stored to the value other than "0", and communication with servo amplifier is
started when the power is turn ON in order of the servo amplifier, QD75.
After the servo parameter stored in the flash ROM is transmitted to the servo
amplifier.
How to transfer the servo parameter setup from PLC program to the
servo amplifier
The motor capacity of servo parameter
(Initial value: "0")
The setting values of the parameters that correspond to the motor capacity of
servo parameter
turned ON or the PLC CPU is reset, after the communication with servo amplifier
is not started.
)
Pr.104
inside the flash ROM are not started when the power is
Pr.104
7 - 17
MELSEC-Q
inside the buffer memory
Pr.104
inside the flash ROM is
Pr.104
inside the flash ROM set to "0".