3. Unplug fan power supply wires from the drive.
4. Release the retaining clips.
5. Lift the fan off.
6. Install the new fan in reverse order. Make sure that the arrow on the fan points up.
6. Install the new fan in reverse order. Make sure that the arrow on the fan points up.
3

Capacitors

The drive intermediate DC circuit employs several electrolytic capacitors. Their lifespan
depends on the operating time of the drive, loading and ambient temperature. Capacitor
life can be prolonged by lowering the ambient temperature.
Capacitor failure is usually followed by damage to the drive and an input cable fuse failure,
or a fault trip. Contact the manufacturer if capacitor failure is suspected. Replacements are
available from the manufacturer. Do not use other than specified spare parts.

Reforming the capacitors

The capacitors must be reformed if the drive has not been powered (either in storage or
unused) for a year or more. See section
out the manufacturing date from the serial number.
For information on reforming the capacitors, see Converter module capacitor reforming
instructions (3BFE64059629 [English]), available on the Internet (go to
and enter the code in the Search field).

Control panel

Cleaning the control panel

Use a soft damp cloth to clean the control panel. Avoid harsh cleaners which could scratch
the display window.

Replacing the battery in the control panel

A battery is only used in the assistant control panel that support the clock function. The
battery keeps the clock operating in memory during power interruptions.
The expected life for the battery is greater than ten years.
Note:
The battery is NOT required for any control panel or drive functions, except the clock.
1. Remove the control panel from the drive. See section
Maintenance and hardware diagnostics 103
5
4
Type designation label (page 33)
Control panel (page
for how to find
http://www.abb.com
32).

Hide quick links: