Lenovo ThinkSystem SR650 Maintenance Manual page 67

2u rack server
Hide thumbs Also See for ThinkSystem SR650:
Table of Contents

Advertisement

Server model: twenty-four 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, one 8i RAID
adapter, one 24i RAID adapter
Figure 41. Cable routing for server models with twenty-four 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly,
one 8i RAID adapter, and one 24i RAID adapter
Cable
1
Power cable for front backplane 1
2
SAS signal cable for front
backplane 1
3
SAS signal cable for front
backplane 2
4
Power cable for front backplane 2
5
Power cable for front backplane 3
From
Power connector on front backplane
1
SAS 0 and SAS 1 connectors on front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 2
Power connector on front backplane
2
Power connector on front backplane
3
To
Backplane power connector 1 on the
system board
C0 and C1 connectors on the 8i RAID
adapter installed on the RAID adapter
slot
C0 and C1 connectors on the 24i
RAID adapter installed on PCIe slot 5
Backplane power connector 2 on the
system board
Backplane power connector 3 on the
system board
.
Chapter 2
Server components
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents