System board jumpers

The following illustration shows the location of the jumpers on the system board of your server.
Figure 17. System board jumpers
Table 8. Jumper description
Jumper name
1
Clear CMOS jumper
2
Override power-on
password jumper
3
TPM/TCM physical
presence jumper
* TPM: Trusted Platform
Module
* TCM: Trusted
Cryptography Module (for
China only)
4
Force XCC update jumper
5
Force XCC reset jumper
Important:
26
ThinkSystem SR650 Maintenance Manual
Jumper
Jumper setting
number
J95
• Pins 1 and 2: The jumper is in default setting.
• Pins 2 and 3: Clear the real-time clock (RTC) registry.
J50
• Pins 1 and 2: The jumper is in default setting.
• Pins 2 and 3: Override the power-on password.
J46
• Pins 1 and 2: The jumper is in default setting.
• Pins 2 and 3: TPM/TCM physical presence is asserted.
J45
• Pins 1 and 2: The jumper is in default setting.
• Pins 2 and 3: Force the Lenovo XClarity Controller o update to the
latest version.
J181
• Pins 1 and 2: The jumper is in default setting.
• Pins 2 and 3: Reset the Lenovo XClarity Controller.