Mitsubishi Electric MELSEC iQ-R Series Configuration Manual page 49

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
CC-Link IE Field Network
*5
CC-Link
*5
Serial communication
AnyWireASLINK master module
BACnet module
CANopen module
*1 When the CC-Link IE Controller Network function of the RJ71EN71 is used, there are restrictions on the firmware versions of the
RnCPU, the C Controller module, and the RJ71EN71. ( Manual for each module)
*2 These modules occupy two slots. When these modules are used with the RnCPU or the C Controller module, there are restrictions on
each firmware version. ( User's Manual (Application) for the CPU module used)
*3 When the RJ71EN71 is used with a remote head module, there are restrictions on network combinations. ( MELSEC iQ-R Ethernet/
CC-Link IE User's Manual (Startup))
*4 When a redundant system is built with a master station of CC-Link IE Field Network, these modules cannot be used with a remote head
module.
*5 When a redundant system is built with these modules, there are restrictions on the firmware version. ( Manual for each module)
*6 Depending on the CPU module used, there are restrictions on the firmware version of the MES interface module. ( MELSEC iQ-R
MES Interface Module User's Manual (Application))
*7 The method for enabling parameters differs depending on the firmware version of the C Controller module. ( MELSEC iQ-R C
Controller Module User's Manual (Startup))
*8 "Target" cannot be set to "RPDO" and "TPDO" under "Refresh Setting" in "Module Parameter". Parameter error (error code: 2220H)
occurs.
*9 Use the RnCPU with firmware version "28" or later, the RnENCPU with firmware version "17" or later, and the RnPCPU with firmware
version "12" or later. When the CPU module with these firmware versions or earlier is used, there is the restriction on *8.
■ Blank cover module
Item
Blank cover module
MELSEC-Q series
The following table lists the MELSEC-Q series modules and extension cables which can be used in the MELSEC iQ-R series
system.
When a MELSEC-Q series module is used, refer to the following.
Page 158 How to Use MELSEC-Q Series Modules
Item
Base unit
Extension base unit
Q series large type extension base unit
Q series large type extension base unit (AnS series size)
Extension cable
Power supply module
Model
*5
RJ71GF11-T2
RJ71EN71
RJ61BT11
RJ71C24, RJ71C24-R2, RJ71C24-
R4
RJ51AW12AL
RJ71BAC96
RJ71CN91
Model
RG60
*5
*5
Rn
Rn
RnP
RnP
Rn
EN
(P)
(R)
MT
*9
*9
*9
Rn
Rn
RnP
RnP
Rn
EN
(P)
(R)
MT
Model
Q52B, Q55B, Q63B, Q65B, Q68B, Q612B
Q55BL, Q65BL, Q68BL
Q55BLS, Q65BLS, Q68BLS, Q55BLS-D, Q65BLS-D, Q68BLS-D
QC05B, QC06B, QC12B, QC30B, QC50B, QC100B
Q61P, Q61P-A1, Q61P-A2, Q62P, Q63P, Q64P, Q64PN, Q61P-D
1 SYSTEM CONFIGURATION
1.2 System Configuration Specifications
Rn
Rn
Rn
Rem
Rem
NC
C
SF
(R)
*8
Rn
Rn
Rn
Rem
Rem
NC
C
SF
(R)
1
47

Advertisement

Table of Contents
loading

Table of Contents