Precautions - Mitsubishi Electric MELSEC iQ-R Series Configuration Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Precautions

This section describes precautions for using the following modules.
For details, refer to the manual for the module used.
Base unit
In "Module Name" on the "System Monitor" window, the model of each extension base unit is not displayed but "Extension
Base" is displayed.
■ Q series large type extension base unit and Q series large type extension base unit (AnS
series size)
Select the module which can be used to each extension base unit on "Module Configuration". When the Q series large type
blank cover is used, select the module with the Q series large type blank cover.
Power supply module
In "Module Name" on the "System Monitor" window, the model of each power supply module is not displayed but "Power" is
displayed.
I/O modules
■ High-speed input modules
• When a high-speed input module is used as a high-speed input module, select the following model in "Module
Configuration" in accordance with on or off of a noise filter. (The module operates with the default setting (input response
time: 0.2ms) when on or off of the noise filter does not correspond to on or off of the model on "Module Configuration".)
Model
QX40H
QX70H
QX80H
QX90H
• When a high-speed input module is used as an interrupt module, select "QI60" in "Module Configuration". (The module
operates with the default setting (input response time: 0.2ms) when the noise filter is used at off.)
• When high-speed input modules are used as interrupt modules, set the number of modules to be used in "I/O Assignment
Setting" in the [I/O Assignment] tab on the "System Parameter" window.
■ Interrupt modules
• When multiple interrupt modules are used, set the number of modules to be used in "I/O Assignment Setting" in the [I/O
Assignment] tab on the "System Parameter" window.
■ Large type AC input module, large type contact output module, large type triac output
module, and large type transistor output module
• Place the module that can be mounted on the extension base unit on the "Module Configuration" window.
Analog-digital converter module
Logging data A/B side storage complete pointer detection, an interrupt factor of the Q64ADH, cannot be used as an interrupt
pointer.
High-speed counter modules and pulse input modules
Check the latest error code with the system monitor because error codes for the QD63P6 and QD60P8-G cannot be checked
in the module diagnostics. When multiple errors occur, refer to the buffer memory and check the error.
APPX
166
Appendix 5 How to Use MELSEC-Q Series Modules
Model displayed on GX Works3
When the noise filter is turned on
QX40H(NoiseF_ON)
QX70H(NoiseF_ON)
QX80H(NoiseF_ON)
QX90H(NoiseF_ON)
When the noise filter is turned off
QX40H(NoiseF_OFF)
QX70H(NoiseF_OFF)
QX80H(NoiseF_OFF)
QX90H(NoiseF_OFF)