NEC Univerge SV8100 System Hardware Manual page 127

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

4-10
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
2.6.3.2 Port Defaults
With the default settings, the ports are assigned as follows:
Station Ports
Virtual Station Ports
Trunk Ports
In the initial configuration:
♦ All Programmable Function keys are line keys (e.g., key 1 is
line 1).
♦ All trunks are loop start DTMF.
2.6.3.3 Setting Up Extension Circuit Types
Run Program 10-03 to set up extension circuit types as required.
The system automatically detects and assigns most circuit types
when the device is connected.
1. Dial 10-03-01.
2. Press TRANSFER to Select the slot, port or channel (with
DLCA Blades) to be programmed.
3. Set the terminal type or option as needed.
As the system recognizes the extension devices automatically,
when replacing the type of device connected, the type must be
undefined in Program 10-03 prior to connecting the new device.
For example, if a port was previously used for a telephone and a
DSS Console is to be installed in that same port, the telephone
must first be undefined in Program 10-03 before the console is
connected.
Table 4-4 Default Port Settings
Port 1~99 : 200~298
Port 100~300 : 299~499
Port 301~512 : 5000~5211
Port 1~256 : No Setting
1~200
If the system has DSS Consoles, Program 30-02
must be used to define DSS extension assignments.
Installing the SV8100 Blades
http//vietpro.com.vn
UNIVERGE SV8100