ABB Endura AZ30 series Programming Manual page 111

Integral probe and remote transmitter combustion oxygen monitor
Hide thumbs Also See for Endura AZ30 series:
Table of Contents

Advertisement

Refer to Section 6.4.5, page 52
Diagnostics
Menu
Display
From inside
front cover
Exit
Select
Display
Language
Operator Page 1
Operator Page 2
Autoscroll
Time & Date
Daylight Saving
Contrast
Display Test
Select
Back
Language
English
Deutsch
Français
Español
Italiano
Back
Operator Page 1 (2)
Display Mode
1st Line View
Display Mode
2nd Line View
1st Line View
3rd Line View
2nd Line View
Bargraph
3rd Line View
Bargraph
Back
Autoscroll
Autoscroll
Enabled
Back
Time & Date
Format
Time & Date
Back
Daylight Saving
Region
Daylight Start
Daylight End
Back
Contrast
Contrast
Back
1
Display Test
Back
Refer to Section 6.4.6, page 57
Menu
5
6
Process Alarm
Exit
Select
Process Alarm
Alarm #1
Alarm #2
Alarm #3
Alarm #4
Back
Select
Alarm 1
Type
Trip
Hysteresis
Back
Select
Alarm 2
Type
Trip
Hysteresis
Select
Back
Select
Alarm 3
Type
Trip
Hysteresis
Back
Select
Select
Alarm 4
Type
Trip
Hysteresis
Edit
Back
Select
Select
Select
Key:
50%
1 Not displayed at Read Only level
OK
2 Displayed only if an option board is fitted.
3 The probe type used with the transmitter.
4 The transmitter option card fitted.
OK
Refer to Section 6.4.7, page 58
Refer to Section 6.4.8, page 65
Menu
7
Input/Output
Exit
Select
Exit
Input/Output
Relay #1
HART
Relay #2
Cyclic Output
Digital I/O #1
Back
Digital I/O #2
Current Output #1
Current Output #2
Select
Back
Relay #1 (2)
Relay Assignment
Polarity
Back
Select
2
Digital I/O #1
Mode
Output Assignment
Polarity
Input Function
Type
Sequence
Back
Select
2
Digital I/O #2
Mode
Output Assignment
Polarity
Input Function
Type
Sequence
Back
Select
Current Output #1
Source
Type
Eng. Range Hi
Eng. Range Lo
Elec. Range Hi
Elec. Range Lo
Output Failure
Failure Current
Output #1 Test
Back
Select
2
Current Output #2
Source
Eng. Range Hi
Eng. Range Lo
Elec. Range Hi
Elec. Range Lo
Output Failure
Output #2 Test
Back
Select
Refer to Section 6.4.9, page 67
Menu
8
Communication
Select
Exit
Communication
Serial Number
Date of Manufacture
Date of Last Cal.
Select
Probe Type
AutoCal Hardware
HART
Transmitter Options
Main Board Version
HART Poll Address
Software Version
HART Device ID
HART Tag
Back
HART Device Message
Serial Number
HART Descriptor
Device Install Date
Serial Number
Final Assembly No.
Back
Back
Select
Date of Manufacture
Cyclic Output
Date of Manufacture
Interval
Back
Assignment
Date of Last Cal.
Back
Select
Date of Last Cal.
Back
3
Probe Type
AZ20 & Integral Tx
AZ20 & Remote Tx
AZ25 & Remote Tx
AZ30 & Integral Tx
AZ30 & Remote Tx
AZ35 & Remote Tx
Back
AutoCal Hardware
None
Internal
Remote
Back
4
Transmitter Options
None Fitted
Digital I/O
Analog Output
Back
Main Board Version
Main Board Version
Back
Software Version
Software Version
Back
Menu
9
Device Info
Select
Device Info
Select
xxx.x
xxx.x
XXXX:XX:XX
XXXXX
XXXXX

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents