GE AF-650 GP Design And Installation Manual page 67

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Application Set-Up Examples
Function
Check that the ramp settings are within frequency
converter capabilities and allowed application operating
specifications.
Set acceptable limits for the motor speed and frequency. Parameter F-18 Mot
4) Configure the Speed Control and select the motor control principle
Activation of Speed Control
Selection of Motor Control Principle
6
6
5) Configure and scale the reference to the Speed Control
Set up Analog Input 53 as a reference Source
Scale Analog Input 53 0 RPM (0V) to 1500 RPM (10 V)
6) Configure the 24 V HTL encoder signal as feedback for the Motor Control and the Speed Control
Set up digital input 32 and 33 as encoder inputs
Select terminal 32/33 as motor feedback
Select terminal 32/33 as Speed PID feedback
7) Tune the Speed Control PID parameters
Use the tuning guidelines when relevant or tune
manually
8) Finished!
Save the parameter setting to the keypad for safe
keeping
Table 6.17 Programming Order
64
Parameter
Setting
Parameter F-07 Acc
Default setting
el Time 1
default setting
parameter F-08 Dec
el Time 1
0 RPM
or Speed Low Limit
1500 RPM
[RPM]
60 Hz (default 132 Hz)
parameter F-17 Mot
or Speed High Limit
[RPM]
parameter F-03 Max
Output Frequency 1
Parameter H-40 Conf
[1] Speed closed loop
iguration Mode
Parameter H-41 Mot
[3] Flux w motor feedb
or Control Principle
Parameter F-01 Freq
Not necessary (default)
uency Setting 1
AN-1#
Not necessary (default)
Parameter E-05 Ter
[0] No operation (default)
minal 32 Digital
Input
parameter E-06 Ter
minal 33 Digital
Input
Parameter H-42 Flu
Not necessary (default)
x Motor Feedback
Source
Parameter PI-00 Spe
Not necessary (default)
ed PID Feedback
Source
PI-0#
See the guidelines below.
Parameter K-50 Key
[1] All to keypad
pad Copy
DET-767c All rights reserved.