Using Z-Wave Devices and Scenes (cont'd)
Scene Options
Set the TIME: In the Trigger/Condition box, press Add. Press the TIME button > Set the
occurrence.
If ONCE > Enter Date; if REPEATED > choose days of the week; if BY CLOCK > press on the
"Hour/Minutes" displayed and enter the Start and End Time > press on AM/PM; if SUNRISE or
SUNSET > press the option. Check the Critical Event check box to record and store a maximum
of two events even when the SD card is not available. If more than 2 critical events occur, then the
older one is replaced by the latest event.
Notes:
The Sunrise/Sunset feature is dependent on the "Region" selected in the "Weather Forecast"
section and requires internet access for accuracy.
BY CLOCK allows you to activate the scene for a specified period of time.
Set the Security Mode: In the Trigger/Condition/Action box, press Add. Press the SECURITY
button and select from DISARM, AWAY, STAY, NIGHT, AWAY SECURED or ALARM. Enter
User Code, if required.
Notes:
AWAY triggers upon arming away.
AWAY SECURED triggers when exit delay has expired.
Set the Thermostat: In the Trigger/Condition/Action box, press Add. Press the THERMOSTAT
button and select a Thermostat Device from the drop-down menu. Use the ABOVE and BELOW
buttons to increase/decrease the temperature or press the Temperature Value box and enter 2
digits for the desired temperature.
Notes:
Test thermostats first to ensure proper function in the "Scene."
Some thermostats do not update temperature status automatically (i.e., Wayne Dalton).
Set the Door Locks: In the Trigger/Condition/Action box, press Add. Press the DOOR button and
select a Door Device from the drop-down menu. Select LOCKED or UNLOCKED or CODE
UNLOCKED.
Notes:
Motorized door lock bolts physically lock and unlock when activated, but if the door lock
installed is a non-motorized type, activation allows the door to be manually unlocked without
a
key.
See "Compatible Devices" section later in this document.
When using a Kwikset Smartcode electronic deadbolt door lock (in a Scene that is programmed
to trigger when unlocked) the Scene does not trigger if using a key; enter a user code.
Set the Zones: In the Trigger/Condition box, press Add. Press the ZONES button and select a zone
from the drop-down menu. Select Restore, Alarm or Fault.
Note: Do not use 24 hr silent zone restore/fault in the pre-condition and trigger fields on
commercial panels.