Step 2: Configure VideoBloX Network Settings

Step 3A: Configure the Controller for a Serial Port Connection

Document 800-02573 Rev B
11/2009
To configure VideoBloX network settings:
1.
From the side menu, click VideoBloX Configuration. See
2.
Under Keyboard ID Setting, enter a number between 1 and 32 to set the controller
ID.
3.
Under VB Device Network Setting, enter the IP address and Port Number of the
VideoBloX system.
4.
Click Apply to save the configuration, Cancel to exit without saving, or Default to
restore all factory default values.
5.
Go to either Step 3A or 3B to configure the system for Serial or Ethernet connections
respectively.
Figure 2-9
VideoBloX Configuration Tab
To configure the controller for a serial port connection:
1.
From the side menu Settings:Hardware Config, click Port Settings. See
Figure
2-10.
2.
Under COM1 Settings, select the following from each drop down list as required:
Baud Rate: 1200 bps, 1800, 2400, 4800, 9600, 19200, or 57600
The default for VideoBloX is 19200.
Parity: none
Stop Bits: 1 bit
Data Bits: 8 bits
Serial Mode: RS422
3.
Click Apply to save the configuration, Cancel to exit without saving or Default to
restore all factory default values.
UltraKey Plus Controller Installation and User Guide
Figure
2-9.
39