Reloading the Access Point Image
If using in-line power, use a Category 5 (CAT5) Ethernet cable to connect your PC to the To Network
Step 5
Ethernet connector on the power injector.
Step 6
Open the access point cover (refer to the
Disconnect power (the power jack for external power or the Ethernet cable for in-line power) from the
Step 7
access point.
Step 8
Press and hold the MODE button while you reconnect power to the access point.
Step 9
Hold the MODE button until the Radio LED turns a red color (approximately 20 to 30 seconds), and
release the MODE button.
Step 10
After the access point reboots, you must reconfigure the access point by using the Web interface, the
Telnet interface, or Cisco IOS commands.

Web Browser Interface

You can also use the Web browser interface to reload the access point image file. The Web browser
interface supports loading the image file using HTTP or TFTP interfaces.
Note

Browser HTTP Interface

The HTTP interface enables you to browse to the access point image file on your PC and download the
image to the access point. Follow these instructions to use the HTTP interface:
Open your Internet browser.
Step 1
Note
Enter the access point's IP address in the browser address line and press Enter.
Step 2
At the prompt, enter the administrator username and password. The default username is Cisco and the
Step 3
default password is Cisco. The username and password are case sensitive. The Summary Status page
appears.
Click the System Software tab and then click Software Upgrade. The HTTP Upgrade screen appears.
Step 4
Click the Browse button to locate the access point image file (such as c1130-k9w7-tar.123-8.JA.tar) on
Step 5
your PC.
Click Upload.
Step 6
For additional information, click the Help icon on the Software Upgrade screen.
Cisco Aironet 1130AG Series Access Point Hardware Installation Guide
3-18
Your access point configuration is not changed when using the browser to reload the image file.
You should disable your browser pop-up blocker.
The access point web-browser interface is fully compatible with Microsoft Internet Explorer
version 6.0 on Windows 98 and 2000 platforms and with Netscape version 7.0 on Windows 98,
Windows 2000, and Solaris platforms.
Chapter 3
Troubleshooting Autonomous Access Points
"Opening the Access Point Cover" section on page
2-11).