Alarm Port Setup Screen; Figure 133 Alarm Port Setup - ZyXEL Communications IES-1248-51 User Manual

Adsl2+ ip dslam
Hide thumbs Also See for IES-1248-51:
Table of Contents

Advertisement

IES-1248-51/51A/53 User's Guide
Table 83 Alarm Event Setup Edit (continued)
LABEL
Severity
Clearable
Apply
Close

39.5 Alarm Port Setup Screen

Use this screen to set the alarm severity threshold for recording alarms on an individual
port(s). The system reports an alarm on a port if the alarm has a severity equal to or higher
than the port's threshold.
To open this screen, click Alarm, Alarm Port Setup.

Figure 133 Alarm Port Setup

252
DESCRIPTION
Select an alarm severity level (critical, major, minor or info) for this alarm. Critical
alarms are the most severe, major alarms are the second most severe, minor
alarms are the third most severe and info alarms are the least severe.
Select this check box to allow administrators to use the management interface to
remove an alarm report generated by this alarm event entry.
Select this check box to keep an alarm report generated by this alarm event in
the system until the conditions that caused the alarm report are no longer
present.
Click Apply to save your changes to the IES-1248's volatile memory. The IES-
1248 loses these changes if it is turned off or loses power, so use the Config
Save link on the navigation panel to save your changes to the non-volatile
memory when you are done configuring.
Click Close to exit the screen without saving your changes.
Chapter 39 Alarm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ies-1248-51aIes-1248-53

Table of Contents