I
NSTALLATION
6.9.5
Aligning the Pole Columns Using a Tire Lever (if required)
CAUTION
44 / 146
In order to connect the pole columns, a tire lever (16) is used to mo-
ve the pole columns.
• Brace the tire lever against the side of the lattice support and
press it against the flange on the crankcase in order to move the
pole columns.
The SF
filling connection can be damaged by contact with the ti-
6
re lever.
Therefore:
- Never position the tire lever against the SF
tion in order to move the pole columns.
16
OI 250 (EN)
filling connec-
6
REV7
/REV7