3.
Align the pin with the arrow mark on the power
unit. Insert the pipe until the release button pops up.
Make sure that the position line is on the tip of the arrow
mark on the power unit, and the arrow mark on the
power unit and the arrow mark on the pipe are facing
each other.
Fig.6
► 1 . Release button 2. Arrow mark on the power unit
3. Pin 4. Position line 5. Arrow mark on the pipe
4.
Turn the lever toward the power unit.
1
Fig.7
► 1 . Lever
Make sure that the surface of the lever is parallel to the pipe.
NOTICE:
Do not tighten the lever without the
attachment pipe inserted. Otherwise the lever may
tighten the entrance of the drive shaft too much and
damage it.
To remove the pipe, turn the lever toward the attach-
ment and pull the pipe out while pressing down the
release button.
Fig.12
Fig.8
► 1 . Release button 2. Lever 3. Pipe
1
2
3
4
5
1
2
Installing or removing the shear
blades
CAUTION:
always wear gloves so that your hands do not
directly contact the blades.
CAUTION:
removing or installing the shear blades.
NOTICE:
When replacing the shear blades, do
not wipe off grease from the crank.
NOTE: Before installing or removing the shear
blades, unfold the attachment so that the attachment
is straight to the pipe.
1.
Attach the blade cover to the shear blades.
1
Fig.9
► 1 . Blade cover
2.
Place the attachment upside down.
3.
Remove 4 bolts with the hex wrench, and remove
the under cover, cover and plate (large).
1
3
Fig.10
► 1 . Bolt 2. Under cover 3. Cover 4. Plate (large)