Click Next to select the Access database that
will be imported into the PostgreSQL
database.
A file – open dialog box will be shown and
will automatically open at the default location
for test results in the PosiChek3 software. If
the database is located somewhere else, use
the browse function to navigate to that
location and select the database.
Click on a database to select it and click
Open. The Import Serial Number screen will
be shown along with the information about
the Access Database.
Click Next to choose the models for import.
The screen will list all of the models in the
selected database that have serial numbers
assigned to them.
Select a row by clicking in it so the whole row
appears highlighted and click the "Choose
Model" button at lower left. The Choose
Model screen will be shown. If the model
that is being exported from Access matches
an existing model in the new PostgreSQL
database, then select it. Otherwise, click the
"New" button and add the model
specifications into the new database.
Continue with this process of selecting the
serial numbers from the access database
and exporting them into the new PostgreSQL
database until all models have been entered.
Once all serial numbers have been
successfully imported into the PostgreSQL
database, click Next.
The software will show the numbers of serial
numbers that were imported, and will show
those that were not imported. Apparatus with
serial numbers already present in the
PostgreSQL database will not be imported.
7. Connect the breathing
apparatus to the Posi
3 USB.
Now that the software is installed and
running, and the Posi 3 USB is assembled, it
is time to connect the breathing apparatus to
the Posi 3 USB. One of the strengths of the
Posi 3 USB is its adaptability. For simpler
tests, the breathing apparatus's facepiece
serves as the only interface between the Posi
3 USB and the breathing apparatus. More
complex tests require the use of a series of
manifolds to deliver pressure levels from
points in the breathing apparatus's airstream
to the Posi 3 USB's internal transducers.
Every breathing apparatus is different, so
specific parts and instructions may be
required for your breathing apparatus to be
connected to the Posi 3 USB.
The Complete SCBA Test requires the
following connections between the SCBA
and the Posi 3 USB: