Cisco 3200 Series Upgrade Manual page 45

Hardware upgrade guide
Hide thumbs Also See for 3200 Series:
Table of Contents

Advertisement

Chapter 3
Replacing Cards in the Cisco ISR 3270 Rugged Enclosure
Figure 3-8
4
1
Serial console cable
3
Right alignment tab
Slowly slide the card stack back until the alignment tabs are flush against the extrusion.
Step 9
Using a small Phillips screw driver, reattach the alignment tabs to the extrusion. Use a torque range of
Step 10
2.5 to 3.5 in-lb.
Tighten the Wedge Loks on the I/O end cap side with a 3/32-inch hex blade.
Step 11
sequence for tightening the Wedge Loks. Use a torque range of 5.5 to 5.7 in-lb when tightening the
Wedge Loks.
Make sure that all the Wedge Loks are secure. Thermal transfer will not occur if any Wedge Lok is loose.
Caution
OL-15983-01
Attaching Alignment Tabs
1
2
3
2
LED cable
4
Right alignment tab
Cisco 3200 Series Router Hardware Upgrade Guide
Card Replacement Process
Figure 3-9
shows the