Tv Install Recess - 45 Degree Elbow On Top Of The Unit - Honeywell Flare Front Series Installation Manual

Table of Contents

Advertisement

TV INSTALL RECESS – 45 DEGREE ELBOW ON TOP OF THE UNIT
When planning a TV recess, clearance to the vent pipe in the chase is critical and needs to be a minimum of 1" to the non-
combustible recessed wall. This is to prevent heat from radiating from the vent to the recessed wall and being transferred to the
TV.
Due to the central location and diameter of the vent (8 inches) on our front facing & see-through models, one of the following
solutions may be necessary to maintain the clearance requirement:
1. The television recess should be no more than 6" inches deep, 12" above the top of the fireplace glass opening. You
must maintain a 1" clearance from your recess to the vent pipe to prevent overheating.
2. Install two 45 elbows directly above the fireplace followed by a minimum 4 ft vertical vent rise. The two small
elbows will move the vertical section back 5 5/8". Note that the 1-inch clearance from the vent applies also to the
back non-combustible wall.
3. Do not use any elbow with an angle larger than 45 degrees.
4. A 4 ft minimum vertical vent must be used after the two 45-degree elbows.
5. Note: Max recess of TV into the cavity should not exceed 6". Recesses exceeding this dimension run the risk of
creating a shelf and hindering air flow above unit, resulting in a wall that may overheat.
6.
The following vent path should be used for Flare Front and Flare See Through only.
60 |
P a g e
4x6
Offset
Rise
5"
13 1⁄2"
5x8
Offset
Rise
5 5⁄8"
15 3⁄8"

Advertisement