VENT RESTRICTOR SETUP

Flare Fireplace direct vent system is equipped with a vent restrictor. Use Chimney Path Installation and Planning on
the next page to determine the right vent restrictor setup for your installation.
Vent restrictor changes and setup should only be done by a certified installer.
The unit leaves the factory with the vent restrictor open.
The vent restrictor is adjusted using a 10mm wrench below the front upper frame.
The vent restrictor setting is from 1 (minimum restriction) to 6 (maximum restriction).
The installer will document the restrictor setting in the end of the installation.
Use the
Signs the vent restrictor needs to be adjusted:
Vent restrictor should be opened if the flame has the following characteristics:
• Flame is excessively tall and lifting.
• Flame lacks movement.
Vent restrictor should be closed if the flame has the following characteristics:
• Flame height is low.
• Flame has excessive movement
38 |
P a g e
vent planning guide
and table to determine the restrictor setting.
Document any change to the restrictor setting.
Contact Flare Fireplaces for support if needed