NEC NEAX2400 IPX Programming Manual page 912

Feature programming manual
Hide thumbs Also See for NEAX2400 IPX:
Table of Contents

Advertisement

Service Conditions (cont'd)
When this service is provided in the network through FCCS groups and NEAX2000 IVS
1.
For general information of this network, refer to "Network Through FCCS Groups and NEAX2000 IVS
in the NEAX2400 IPX No. 7 CCIS System Manual.
2.
The Centralized System Message Report feature for this network may be controlled only by the
Centralized MAT.
See Centralized Maintenance - CCIS [C-167] for explanation of the Centralized MAT.
Note:
3.
By polling from the Centralized MAT connected to the Center Office, the information regarding faults
occurring at all nodes (NEAX2400 IPX and NEAX2000 IVS
4.
When a fault occurs in the NEAX2000 IVS
Office using polling method. To collect detailed information, log-in to the system where the fault
occurred.
5.
The buffer for fault information of the NEAX2400 IPX and that of the NEAX2000 IVS
maximum of 64 calls can be stored in the buffer at each system. Therefore, a fault occurring when the
buffer capacity is full cannot be stored, and the system receives the NACK signal. At that time, the system
resends the information after waiting for a preprogrammed time.
6.
The table below shows the controllability of fault information received from the NEAX2000 IVS
2
NEAX2000 IVS
to
NEAX2400 IPX
NEAX2400 IPX (A) to
NEAX2400 IPX (B) within
an FCCS group
FCCS Group (A) to FCCS
Group (B)
Available when the alarm grade is changed by ASYD, SYS 1, Index 188, bit 1 = 1, and the ALMG command.
Note:
7.
The fault information of NEAX2000 IVS
command.
8.
When the information of faults occurred at all the FCCS groups and the connected NEAX2000 IVS
managed by the Centralized-MAT, the destination of fault message output must be changed to the
designated Center Office (for example, NCN) at each Local Node (including NEAX2000 IVS
Additional information is outlined in Programming.
Programming
STEP 1:
ASYD - System 1:
System 1, Index 38. Designation of mounting the printer.
System 1, Index 39. Designation of System Message Output Port.
System 1, Index 86, Bit 0. Assign Routine Diagnostic Normal End Information Indication (1).
System 1, Index 86, Bit 1. Assign Routine Diagnostic Fault Information Indication (1).
System 1, Index 86, Bits 2 & 3. When Trunk Ineffective Hold has been detected.
00:
All calls other than the basic calls are released an all the information print out.
01:
Only All Printout
10:
All Release & All Printout
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Centralized System Management Report - CCIS
CONNECTION
SMJ/SMN LAMP
METHOD
CCIS
Not Controllable
FCCS
Not Controllable
CCIS
Controllable
2
2
) can be collected.
2
, only the basic fault information is collected from the Center
MENU DISPLAY
ON TOPU
ON MAT
Not Controllable
Controllable
Controllable
received at Center Office is cleared by the RALM/RALMN
2
2
are separate. A
DFTD
COMMAND
Not Controllable
Note
Controllable
Controllable
C-57
2
",
2
:
2
is
2
).
Page 869