Service Conditions (cont'd)
4.
A called station that has the SERIAL CALL feature activated will automatically recall the attendant if the
station switch hook flashes.
5.
This feature is not applicable for tandem connections.
6.
The following services cannot be used while SERIAL CALL - CCIS is activated:
ATTENDANT CAMP-ON WITH TONE INDICATION - CCIS [A-45]
BUSY VERIFICATION - CCIS
CALL HOLD - CCIS / CALL HOLD - D
EXECUTIVE RIGHT-OF-WAY
Programming
ASYD - System 1, Index 43, Bit 4:(1): Allow ATT to reenter loop on serial call.
System 1, Index 186, Bit 4: At the time of serial call, 0/1: ATT Loop Wait/ATT Loop Release.
System 2, Index 7, Bit 2:(1) Serial Call service.
The Serial Call key is the button right of the DEST key.