NEC NEAX 2000 IVS 2 System Manual

NEC NEAX 2000 IVS 2 System Manual

Integrated voice server
Hide thumbs Also See for NEAX 2000 IVS 2:

Advertisement

Quick Links

ND-70918 (E)
ISSUE 1
STOCK # 151987
®
CCIS System Manual
MAY, 2000
NEC America, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for NEC NEAX 2000 IVS 2

  • Page 1 ND-70918 (E) ISSUE 1 STOCK # 151987 ® CCIS System Manual MAY, 2000 NEC America, Inc.
  • Page 2 NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc.
  • Page 3 ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE MAY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 1/5 CCIS System Manual ND-70918 (E)
  • Page 4 ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE MAY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 2/5 CCIS System Manual ND-70918 (E)
  • Page 5 ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE MAY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 3/5 CCIS System Manual ND-70918 (E)
  • Page 6 ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE MAY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 4/5 CCIS System Manual ND-70918 (E)
  • Page 7 ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE MAY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 5/5 CCIS System Manual ND-70918 (E)
  • Page 8: Table Of Contents

    NEAX2000 IVS CCIS System Manual TABLE OF CONTENTS Page LIST OF FIGURES ............LIST OF TABLES .
  • Page 9 TABLE OF CONTENTS Page CHAPTER 2 INSTALLATION ..........PRECAUTIONS.
  • Page 10 TABLE OF CONTENTS Page CALL TRANSFER-ATTENDANT-CCIS..........147 CALLING NAME DISPLAY-CCIS .
  • Page 11 TABLE OF CONTENTS Page CHAPTER 4 CIRCUIT CARD INFORMATION ....... . . 259 HOW TO READ THIS CHAPTER .
  • Page 12: List Of Figures

    LIST OF FIGURES Figure Title Page Figure 1-1 No. 7 CCIS System Outline ..........Figure 1-2 Clock Supply Route .
  • Page 13 LIST OF TABLES Table Title Page Table 1-1 Card Name and Function ..........Table 1-2 System Capacity for No.
  • Page 14: Introduction

    Introduction Purpose INTRODUCTION PURPOSE This manual explains the installation and programming procedure for providing No. 7 Common Channel Inter-Office Signaling (No. 7 CCIS) system to the NEAX2000 IVS /NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER. OUTLINE OF THIS MANUAL This manual consists of five chapters. The contents of CHAPTER 1 through 5 are outlined below. CHAPTER 1 GENERAL INFORMATION This chapter explains the system outline, the name and functions of circuit cards required,...
  • Page 15: Terms In This Manual

    Introduction Terms in This Manual TERMS IN THIS MANUAL Usually, PBX system is designated as “PBX” or “system”. When we must distinguish between the PBX systems, they are designated as follows. IVS: NEAX2000 IVS /NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER IMX: NEAX2400 IMS (IMX)/NEAX7400 ICS M140MX or more/NEAX7400 IMX M240 or more REFERENCE MANUAL During installation, refer also to the manuals below:...
  • Page 16: Chapter 1 General Information

    CHAPTER 1 GENERAL INFORMATION This chapter explains the system outline, the name and functions of circuit cards required, system capacity, time slot assignment condition, system specifications, available service features with No. 7 CCIS, and network structure considerations for CCIS system. NEAX2000 IVS CCIS System Manual Page 3...
  • Page 17: System Outline

    CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE The PBX can be interfaced with a Public Network or Tie Line Network by No. 7 CCIS Signaling. For adding No. 7 CCIS to the system, it is necessary to install the 24/30 channel Digital Trunk Interface (DTI) for a digital network or LDT (Loop Dial Trunk)/ODT (2 wire E&M or 4 wire E&M Trunk) for an analog network via a MODEM, and a Phase Locked Oscillator (PLO) for network synchronization.
  • Page 18: Dti

    CHAPTER 1 GENERAL INFORMATION System Outline The Digital Trunk Interface (DTI) interfaces the PBX directly to a 24/30 channel PCM transmission line. The DTI has the following functions. For 24-DTI: • Unipolar/Bipolar Conversion (AMI Format/B8ZS Format) • Signaling Insertion/Extraction • Alarm Detection/Insertion •...
  • Page 19: Plo

    CHAPTER 1 GENERAL INFORMATION System Outline The Phase Locked Oscillator (PLO) is responsible for providing synchronization between the TDSW and another office. In this system, the internal PLO equipped with the MP card is used. The PLO generates a synchronized clock signal according to the source clock signals supplied from the source office within the network, and supplies the generated clock signal to the TDSW.
  • Page 20: 7 Ccis

    CHAPTER 1 GENERAL INFORMATION System Outline No. 7 CCIS The PBX can provide No. 7 CCIS via either a digital network or an analog network. Regardless of the relevant network being a digital network or an analog network, CCH (Common Channel Handler) to control the common signaling channel is required.