Note
The signal is input to IC501 (pin M14) on the AU-349 board and is output from IC501 (pin number: shown below).
Then the output signal is returned again via the DCP-60 board to IC601 (pin L1) through IC501 (pin number: shown
below) on the AU-349 board.
Error value
Diagnosis
5
Path: Pin A2 → pin A3
Data: 0x55550000
Starting serial output channel: Channel 4 (IC601)
Starting serial output channel: Channel 0 (IC501)
6
Path: Pin A2 → pin A3
Data: 0xaaaa0000
Starting serial output channel: Channel 4 (IC601)
Starting serial output channel: Channel 0 (IC501)
7
Path: Pin A2 → pin A3
Data: 0x55550000
Starting serial output channel: Channel 6 (IC601)
Starting serial output channel: Channel 2 (IC501)
8
Path: Pin A2 → pin A3
Data: 0xaaaa0000
Starting serial output channel: Channel 6 (IC601)
Starting serial output channel: Channel 2 (IC501)
Item5 (System controller block diagnosis)
The system controller block diagnosis tests the following contents.
ID
Diagnosis
0x01
2
I
C communication test (RTC)
0x02
2
I
C communication test (EEPROM)
0x03
2
I
C communication test (power sup-
ply microcomputer)
0x04
2
I
C communication test (sub-micro-
computer of the inside panel)
0x05
I
2
C communication test (sub-micro-
computer of the handle)
0x06
I
2
C communication test (sub-micro-
computer of the rear panel)
0x07
2
I
C communication test (sub-micro-
computer of the outside panel)
0x08
2
I
C communication test (sub-micro-
computer of the viewfinder)
0x09
2
I
C communication test (I/O expand-
er)
PMW-50
Error value
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
-1: Error
Type1/2
Note
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
Continued
3-9