Table 22 - Compared Condition Setting - Honeywell 2MLF-HO2A User Manual

High speed counter module
Table of Contents

Advertisement

5. Internal Memory & I/O Signals
5.1. Internal memory configuration
Setting value (Dec)
4
5
6
7
3.
Compared condition setting (CH0: 8H–9H address, CH1: 21H–22H address)
Classification
CH 0
OUT0
8H
OUT1
9H
82
2MLF-HO2A, 2MLF-HD2A High Speed Counter Module User's Guide
1-phase 1-input 1-multiplication
1-phase 1-input 2-multiplication
1-phase 2-input 1-multiplication
1-phase 2-input 2-multiplication
Table 22 – Compared Condition Setting
Address
CH 1
21H
22H
Setting
value
0
1
2
3
4
5
6
Honeywell
Details
Details
Details
If present value < compared
value, OUT is ON
If present value =< compared
value, OUT is ON
If present value = compared
value, OUT is ON
If present value >= compared
value, OUT is ON
If present value > compared
value, OUT is ON
If compared value1 =< present
value =< compared value2, OUT
is ON
If compared value1 >= present
value, present value >= compared
value2, OUT is ON
R200
May 2010

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2mlf-hd2a

Table of Contents