Probe Length 1.0m to 2.0m
Step
Fully thread the nut onto the central conductor of the process connector. Place a
lock washer between the locknut and the first rod segment and torque the nut
against the rod segment and lock washer to secure the connection.
1
Note: Tighten rod connection point to the following torque:
SLG720 6.0Nm (4.4ft-lbs)
Slide a spacer onto first rod. Connect the rod "end" segment to first rod using a
stud and lock washer. Refer to Detail A of Figure 3-13: SLG720 Coaxial probe
assembly (single outer tube depicted).
2
Note: Tighten rod connection point to the following torque:
SLG720 6.0Nm (4.4ft-lbs)
Slip the coaxial outer tube over the rod and tighten to the process connector.
Note: Tighten connection point to the following torque:
3
SLG720 30Nm (22ft-lbs)
It is recommended that a process compatible thread locking compound
(i.e. Loctite 242) be used on the outer conductor threaded joints.
Insert an end spacer into the end of tube. Align the holes in the end spacer with
4
the holes in the outer tube and insert the 2 locking pins. Refer to Detail B of
3-13: SLG720 Coaxial probe assembly (single outer tube
Probe Length ˃ 2.0m
Step
Fully thread the nut onto the central conductor of the process connector. Place
a lock washer between the locknut and the first rod segment and torque the
nut against the rod segment and lock washer to secure the connection.
1
Note: Tighten rod connection point to the following torque:
Connect the rod segment to first rod using a spacer, a stud and lock washer
as shown in Detail A of Figure 3-13: SLG720 Coaxial probe assembly (single
outer tube depicted).
2
Note: Tighten rod connection point to the following torque:
Slip the "starter" coaxial outer tube over the rod and spacers and secure to the
process connector using the M20x1 thread.
Note: Tighten connection point to the following torque:
3
It is recommended that a process compatible thread locking compound
(i.e. Loctite 242) be used on the outer conductor threaded joints.
Insert an end spacer into the end of tube. Align the holes in the end spacer
with the holes in the outer tube and insert the 2 locking pins. Refer to Detail B
4
of Figure 3-13: SLG720 Coaxial probe assembly (single outer tube
Revision 8
SLG720 6.0Nm (4.4ft-lbs)
SLG720 6.0Nm (4.4ft-lbs)
SLG720 30Nm (22ft-lbs)
SLG 700 SmartLine Level Transmitter User's Manual