Figure 3-9: Rod Probe Assembly - Honeywell SmartLine SLG 700 User Manual

Level transmitter guided wave radar
Hide thumbs Also See for SmartLine SLG 700:
Table of Contents

Advertisement

Rod probe assembly
Rod probes are shipped in segments. The segments are attached to each other with a stud
and a lock washer.
Step
1
2
Note: Tighten each rod connection point to the following torques:
SLG720 6.0Nm (4.4ft-lbs)
SLG726 15Nm (11ft-lbs)
Note: For flanged SLG726 models, ensure the nut does not intrude into the
process connector. See
information.
Central Connector
Revision 8
Fully thread the nut onto the central conductor. Using a lock
washer, thread the first rod segment on to the central conductor.
Torque the nut against rod probe and lock washer to secure the
connection.
Thread the stud into first rod segment end. Using a lock washer
thread the next segment onto the stud. Apply torque to secure
the connection.
Error! Reference source not found.

Figure 3-9: Rod probe assembly

SLG 700 SmartLine Level Transmitter User's Manual
Action
for more
Process Connector
Nut
Lock Washer
Rod Segment
Lock Washer
Stud
Rod End
Page 49

Hide quick links:

Advertisement

Table of Contents
loading