Hazardous Locations Certifications - Honeywell SmartLine SLG 700 User Manual

Level transmitter guided wave radar
Hide thumbs Also See for SmartLine SLG 700:
Table of Contents

Advertisement

9.3 Hazardous Locations Certifications

AGENCY
TYPE OF PROTECTION
Explosion Proof with
intrinsically safe probe:
Class I, Division 1, Groups A, B, C,
D;
Class I, Zone 0/1 AEx d[ia] IIC
T6..T5 Ga/Gb
Ex d[ia] IIC T6..T5 Ga/Gb
Dust Ignition Proof:
Class II, III, Division 1, Groups E,
F, G; T5 or T6
Class II Zone 21 AEx tb IIIC T95
o
DIP A21/II, III /1/EFG/Ex tb IIIC
CSA
T95
cCSAus
Intrinsically Safe:
(Canada and
USA)
Class I, II, III, Division 1, Groups A,
B, C, D, E, F, G; T4
Class 1 Zone 0 AEx ia IIC T4 Ga
Certificate #
70016542
Ex ia IIC T4 Ga
Class I Zone 2 AEx ic IIC T4 Gc
Ex ic IIC T4 Gc
Non-incendive with intrinsically
safe probe:
Class I, Division 2, Groups A, B, C,
D; T6..T5
Class I, Zone 0/2 AEx nA[ia] IIC
T6..T5 Ga/Gc
Ex nA[ia] IIC T6..T5 Ga/Gc
Enclosure: Type 4X/ IP66/ IP67.
Dual Seal in accordance with
ANSI/ISA 12.27.01
Canadian Registration Number (CRN):
Page 166
C
o
C
SLG 700 SmartLine Level Transmitter User's Manual
COMM
PARAMETERS
All
Note 1
4-20 mA / HART
Note 2a
FOUNDATION
Note 2b/2c
Fieldbus / FISCO
4-20 mA / HART
Note 1
FOUNDATION
Note 1
Fieldbus / FISCO
All
All
All SLG 700 models are registered in
all provinces and territories in
Canada.
FIELD
Revision 8

Hide quick links:

Advertisement

Table of Contents
loading