49
Fault code
A003
A004
A005
A006
A007
A009
A011
E
E001
E003
E004
E005
E006
E007
E008
E009
E010
E011
E012
E013
E014
E015
E018
E019
E020
PD201809 AEG GRID-TIED THREE-PHASE SOLAR INVERTER (4-10 kW) V.2-18 EN
Message
Instruction
Grid UV
AC undervoltage
Grid OV
AC overvoltage
Grid UF
AC underfrequency
Grid OF
AC overfrequency
Clock Fail
Clock alarm
Cmd Shut
Manual shutdown
Grid Loss
The public grid disconnects.
Input OV
Input overvoltage
Bus OV
Bus overvoltage
Boost Fail
Voltage-boost fault
Grid OC
AC overcurrent
OTP
Overtemperature
Riso Low
Low isolation impedance
IGBT drv
IGBT drive protection
Int Comm
Internal communication fault
Leek Fail
Huge leakage current
Relay Fault
Relay fault
Fan Fail
Fan fault
Eeprom
Memory error
Dc inject
High DC injection
OutputShort
Output short-circuit
Input OC
Input overcurrent
Incnst
Data consistency fault
PowerReversed
DC power reversed
Fault analysis
Low voltage of the public grid
High voltage of the public grid
Low frequency of the public grid
High frequency of the public grid
Wrong setting
Stop by the operation panel or upper PC
Check if inverter AC connection is OK
DC input overvoltage
Internal bus voltage
Voltage-boost fault of the inverter
Internal AC overcurrent
Internal overtemperature
Low isolation impedance of the external
port system
IGBT drive protection of the inverter
Master-slave DSP communication
disabled
Error of master-slave DSP check bit
Huge leakage current of the system or
inverter
Internal relay fault
Internal fan fault
Internal memory error
High DC injection during AC output
Output short-circuit
DC input overcurrent
Inconsistent grid voltage, frequency,
leakage current or AC/DC injection
DC power reversed
49