MAN0443.P65 Issue 13 Aug 04
05701-M-5001 A02279
CHAPTER 6 - OPERATING INSTRUCTIONS
21/07/97 11:06
Slot
Card type
Sensor type
S/W
Serial No
Range
Units
Sensor
Gas
Tag
First span
Last span
Cal. rem.
A1
A2
A3
STEL
Threshold
Value
Time interval
LTEL
Threshold
Value
RATE
Threshold
Value
Max signal
Min signal
Present signal
Relay Interface
RL 1 Norm. energised
RL 2 Norm. de-energised
RL 3 Norm. de-energised
RL 4 Norm. de-energised
RL 5 Norm. de-energised
RL 6 Norm. de-energised
RL 7 Norm. de-energised
RL 8 Norm. de-energised
Notes: 1. The information printed will vary slightly depending on the
type of sensor drive module fitted to the channel card.
2. If an RS 232 device is not connected or is not able to accept
characters, the selected control card display will show XXXX.
** Card info **
: 01
: 5701
: 4-20 mA
: v02.40
: 22411C01
: 0 - 100
: %LEL
: Series 2000 Combustible
: Methane
: Vent 23C
: 21/07/97
: 21/07/97
: 06 months
: 0020 %fsd
: 0050 %fsd
: 0075 %fsd
: 010.0 %fsd
: 0.000 %fsd
: 10 min.
: 010.0 %fsd
: 0.000 %fsd
: 05.0 %fsd
: -0.074 %fsd
: 026.2 %fsd
: 000.0 %fsd
: 8.0 %fsd
: High Integrity
6 - 10
5701 Control System