Cisco GS7000 Installation And Configuration Manual page 68

Hub/node status monitor/local control module
Table of Contents

Advertisement

Chapter 4 Management Via SNMP
heOpSwitchInputTable
This section explains the implementation of the heOpSwitchInputTable.
heOpSwitchInputIndex - Index one indicates PathA. Index two indicates PathB.
The instance displays the slot number and the index. Therefore, if an optical switch
is in slot 10, then 10.1 indicates information for PathA and 10.2 gives the data for
PathB.
OID 1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.1
heOpSwitchInputOpticalLevel - The value of this OID is the measured optical
input power for the optical switch in 0.1 dBm units.
OID 1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.2
heOpSwitchSetInputPowerThreshold - The value of this OID is the input power
switchover point for this input in 0.1 dBm units.
OID 1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.3
heOpSwitchInputStatus - This OID gives the integral status of the input. The value
is fault (2), if the input levels are not in the nominal range. Otherwise, it is normal
(1).
OID 1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.4
heOpSwitchInputDescription - The value of this OID for the GS7000 optical switch
is either PathA or PathB.
OID 1.3.6.1.4.1.5591.1.11.1.4.1.1.2.1.5
heOpSwitchOutputTable
This section explains the implementation of the heOpSwitchOutputTable.
heOpSwitchOutputDescription - This OID is read-only and is always set to Output.
54
OL-29937-01

Advertisement

Table of Contents
loading

Table of Contents