Equipment
EDFA
Optical Switch
Module in slot
The following table indicates the default values for the analog properties table.
Note: In the case of an EDFA, the specific module installed in the Hub/Node will
govern the actual ranges for particular thresholds.
Name
fnLinePowerVoltage
commonInternalTemperature
commonForwardPathReceiveLevel
fnReturnLaserOpticalPower
fnOpticalReceiverPower
fnDCPowerVoltage (-6Vb)
fnDCPowerVoltage (5Vb)
fnDCPowerVoltage (8Vb)
fnDCPowerVoltage (24Vb)
Overall Limits – specific limits
depend on the EDFA module
installed
heOpAmpInputPower
heOpAmpLaserTemp
heOpAmpLaserBiasCurrent
(relative)
heOpAmpLaserOutputPower
heOpAmpLaserTECCurrent
heOpSwitchInputOpticalLevel
heCommonTemperature
44
Parameter OID
heOpAmpLaserTECCurrent
heOpSwitchInputOpticalLevel
heCommonTemperature
Major
Minor
Hi
Hi
80
74
80
50
260
240
23
23
17
17
-51
-52
64
64
96
95
274
269
450
250
450
250
-1
-10
220
200
3000
2000
140
130
750
650
Thresholds Changed
Alarm
Alarm
Alarm
Minor
Major
Dead
Lo
Lo
band
40
36
2
-38
-40
2
-200
-250
5
5
5
1
5
5
0
-67
-68
1
52
51
1
77
75
1
229
224
2
-10
-160
10
-10
-200
10
na
na
1
-31
-200
1
-2000
-3000
10
-90
-100
50
-400
-500
50
Code
RW
RW
RW
Units
VAC
degC
0.1 dBmV
mW
mW
0.1 VDC
0.1 VDC
0.1 VDC
0.1 VDC
0.1 dBm
0.1 degC
mA
0.1 dBm
mA
0.1 dBm
degC