Upper Separation Finger Unit / Upper Separation Finger - Toshiba e-STUDIO556 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:
Table of Contents

Advertisement

(4)
Open 2 clamps and remove 2 connectors.
(5)
Remove 2 screws and take off the bracket.
Note:
When installing the bracket, be sure that the
harnesses are not caught.
(6)
Pull out the IH coil.
Note:
When installing the IH coil, be sure that the
marks "C" and "S" of the power supply
harnesses come at the left side.
4.10.5

Upper separation finger unit / Upper separation finger

(1)
Take off the fuser unit.
(
P.4-96 "4.10.2 Fuser unit")
(2)
Take off the cleaning web unit.
(
P.4-97 "4.10.3 Cleaning web unit /
Cleaning web")
(3)
Remove 2 screws to take off the fuser unit
cover (front).
(4)
Remove 2 stepped screws. Then take off the
upper separation finger unit and a crank
bracket by sliding them to the rear side.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
Clamp
Connector
Fig. 4-281
C ( Blue )
S ( Red )
Fig. 4-282
Screw
Upper separation finger unit
Crank plate
Fig. 4-283
4 - 101
Bracket
Screw
IH coil
Black
Screw
e-STUDIO556/656/756/856(Ver03)