(6)
Remove 1 screw, move the fuser unit
forward and lift it off upward.
Notes:
1. When installing or taking off the fuser unit,
grab the section "A" in the figure.
2. Be sure that the temperature of the fuser
unit has lowered enough before taking it
off. If the unit still heated should be taken
off, wear a pair of gloves before working.
3. Hold B sections of the fuser unit when
installing/removing it.
4.10.3

Cleaning web unit / Cleaning web

(1)
Remove 2 black screws to take off the
cleaning web unit.
Note:
The cleaning web unit can be taken off
without removing the fuser unit.
(2)
Remove 4 E-rings. Then remove 4 bushings
to take off the cleaning web.
(3)
Remove 1 E-ring, 1 bushing, 1 E-ring, 2
gears, 1 pin, and 1 bushing in order from the
shaft.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
B
Fig. 4-273
Screw
Fig. 4-274
E-ring
E-ring
Fig. 4-275
4 - 97
A
Screw
Cleaning web
E-ring