(6)
Disconnect 1 connector and take off the
scanner unit cooling fan.
4.3.16

Platen sensor (S53)

(1)
Take off the top rear cover.
(
P.4-3 "4.1.6 Top rear cover")
(2)
Take off the rear cover.
(
P.4-5 "4.1.13 Rear cover")
(3)
Remove 1 clip to take off the actuator.
(4)
Disconnect 1 connector and release 2
latches. Then take off the platen sensor.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
Scanner unit
cooling fan
Fig. 4-74
Actuator
Clip
Fig. 4-75
Platen sensor
Fig. 4-76
4 - 27