PROMPTS
Open/Close Zone
28
(0)_
Zn1 Trigger Type
29
(V+)_
Restore Zn1 Y/N
30
(Y)_
Delay Zn1 (secs)
31
(00)_
Rpt Zn1 ONLY if
32
Armed (N)_
Invert Zn2 Y/N
33
(N)_
Restore Zn2 Y/N
34
(Y)_
Delay Zn2 (secs)
35
(00)_
Rpt Zn2 ONLY if
36
Armed (N)_
Zn3 Trigger Type
37
(V+)_
Invert Zn3 Y/N
38
(N)_
Restore Zn3 Y/N
39
(Y)_
Delay Zn3 (secs)
40
(00)
4204/
ZONE
OPTIONS
2-4204
TRIG.
Zone Trig: [3-7]
X
X
4204: [1-4]
2-4204:
[1-8]
[0] = not used
• (EOLR)
X
• (V+)
• (V–)
[Y], [N]
X
X
[01-15]
X
X
[00] = no delay
[Y], [N]
X
X
[Y], [N]
X
[Y], [N]
X
X
[01-15]
X
X
[00] = no delay
[Y], [N]
X
X
• (EOLR)
X
• (V+)
• (V–)
[Y], [N]
X
[Y], [N]
X
X
[01-15]
X
X
[00] = no delay
Section 3: Programming the Communicator
DESCRIPTION
Enter the zone number to be used for open/close
(arm/disarm) reports. This zone assignment must
be unique from the Telco zone selected in Prompt
27.
Zone Trigger Mode: If any zone is programmed for
"report only if armed," zone 7 cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8
cannot be used.
NOTE: Connect an open/close (arm/disarm) trigger
(or relay output) from the control panel to the
open/close zone.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Enables restore reporting for zone 1.
Defines the reporting delay in seconds for
zone 1.
Reports alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
Inverts the alarm and normal states of the zone 2
trigger; otherwise uses normal input signal.
Enables restore reporting for zone 2.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for
zone 2.
UL/ULC: Must be set to "00."
Reports alarms on zone 2 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 2.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 3
trigger; otherwise uses normal input signal.
Enables restore reporting for zone 3.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for
zone 3.
UL/ULC: Must be set to "00."