Ecp Status Codes - Honeywell GSMV4G Installation And Setup Manual

Intellipath series 4g gsm communicator
Table of Contents

Advertisement

PROMPTS
Enable Zn6 Y/N
30
(N)_
Zn6 Trigger Type
31
(V+)_
Invert Zn6 Y/N
32
(N)_
Restore Zn6 Y/N
33
(Y)_
Delay Zn6 (secs)
34
(00)_
Enable Zn7 Y/N
35
(N)_
Zn7 Trigger Type
36
(V+)_
Invert Zn7 Y/N
37
(N)_
Restore Zn7 Y/N
38
(Y)_
Delay Zn7 (secs)
39
(00)_
Review? Y/N
40

ECP Status Codes

When the communicator is configured for ECP mode, it sends status messages to the control
panels for battery, power, tamper, and network connectivity failures. Some of the control
panels, (e.g., VISTA-10P, VISTA-15P and VISTA-20P Series) display these on the keypad as
"LngRng Radio" followed by a 4-digit code (listed below). In addition, the Contact ID codes
(listed in Appendix B) for these conditions are sent to the central station by the
communicator.
UL
The information in the following table is based on the VISTA-20 which has not been evaluated
with this communicator.
STATUS CODE
0000
0880
0005
000F
OPTIONS
[Y], [N]
Enables alarm reporting for zone 6.
If [N], skip to Prompt 35: "Enable Zn7."
• (V+)
Selects the triggering method for this zone input.
• (V–)
Press the [space] key to scroll through choices.
• (EOLR)
[Y], [N]
Inverts the alarm and normal states of the zone 6 trigger; otherwise
uses normal input signal.
Enables restore reporting for zone 6.
[Y], [N]
UL/ULC: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for zone 6.
UL/ULC: Must be set to "00."
[00] = no delay
[Y], [N]
Enables alarm reporting for zone 7.
If [N], skip to Prompt 40: "Review."
• (V+)
Selects the triggering method for this zone input.
• (V–)
Press the [space] key to scroll through choices.
• (EOLR)
Inverts the alarm and normal states of the zone 7 trigger; otherwise
[Y], [N]
uses normal input signal.
[Y], [N]
Enables restore reporting for zone 7.
UL/ULC: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for zone 7.
[00] = no delay
UL/ULC: Must be set to "00."
Reviewing Programming Mode Entries
[Y] = review
To review the programming options, press [Y]. The programming
[N] = exit
prompts are displayed again. Use the up/down arrow keys to scroll
through the program fields without changing any of the values. If a
value requires change, simply type in the correct value. When the
last field is displayed, the "REVIEW?" prompt again appears.
To exit the programming mode, press [N] in response to the
"REVIEW?" prompt, and refer to Exiting Programming Mode
paragraph at the end of this section.
Table 3-3. Common ECP Keypad Display Status Codes
Control panel lost communication with communicator.
Communicator tamper detected (cover removed).
Communicator has lost contact with AlarmNet-G network.
Communicator is not registered; account not activated.