GSMV4G/GSMVCN4G Installation and Setup Guide
PROMPTS
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
(Y/N)_
Device Mode
9
(ECP)_
NOTE: In order for the Multi Mode, Remote Access, and Keypad Address programming fields to appear an account
must be created in the AlarmNet Direct website and "Remote Access" must be enabled for the comm device.
Users can receive email notification of system events by using the Multi-Mode feature. In ECP mode, this is
accomplished through emulation of a 4204 relay module, or two 4204 relay modules.
• When "4204-sourced" is selected, the user can be notified of up to four events, plus two additional events if using
the optional communication device zones of 6 and 7.
• When "2-4204-sourced" is selected, the user can be notified of up to eight events. The Multi-Mode address must
match the address of a relay module enabled in the control panel (although you don't actually connect a module).
If using "2-4204-sourced," the address of the second module is automatically assigned the next device address
after the first 4204.
• When "Enhanced Reports" is selected, a device address of 25 should be selected.
Make sure the addresses are also enabled in the control panel. Program outputs to trigger on system events the
user would like to be notified of through Output Device (Relay) programming in the control panel.
These events are configured at the AlarmNet Total Connect website at:
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace
Central Station reporting of critical events (alarms, troubles, etc.).
UL / ULC
Multi-Mode has not been evaluated by UL or ULC.
Multi Mode
10
(Disabled)_
Multi Mode Addr
11
(12)_
Important Information Regarding Primary and Secondary Accounts (Questions 12-18)
Account information is provided by the central station administrator. If the control panel supports secondary
account reporting, you will need secondary account information. The City ID, CS ID or Subscriber ID of the
3-4
OPTIONS
[0-9, A-F, N, S,
This prompt is displayed if [Y] was pressed in Prompt 4 or 5.
T, X, Y]
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
[0-9, A-F, N, S,
Re-enter the password as confirmation.
T, X, Y]
If the password doesn't match the first entry, the following is
displayed followed by the "Exit Prog. Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed directly.
[Y], [N]
Exits program mode.
Press [N] to go back to Prompt 3.
[ESC]
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in this section.
Press the [space] key to scroll through the modes of
• ECP
[ENTER] to select ECP mode.
• Zone Trig.
• 4204 Emu
IMPORTANT, if either Zone Trig, 4204 Emu, or Two 4204s device
• Two 4204s
mode is desired, use Table 3-4 for programming.
Important Information Regarding Multi-Mode Options
• Disabled
Enable if you want system events sent by email to the user. Select
"4204 Sourced" to send up to four events (plus two additional reports
• 4204 Sourced
triggered by optional hardwire zones 6 and 7), or "2-4204 Sourced"
• 2-4204 Sourced
to send eight events.
• Enhanced
Disable for normal alarm processing and go to Prompt 12: "Primary
Reports
City ID".
Select "Enhanced Reports" to enable reporting to TC2 web services.
Note, to use "Enhanced Reports" ensure the control panel is Total
Connect 2.0 Ready.
[01-30]
This address must be programmed if using the Multi- Mode feature.
The address must be unique from the normal communicator (or
LRR) device address, and the Keypad Address used for Remote
Access or Direct Wire downloading. The address used must also be
enabled as a 4204 relay module in Vista and First Alert control
panels. See Important Information above.
DESCRIPTION
https://services.alarmnet.com/TotalConnect
operation.
Press