Honeywell GSMV4G Installation And Setup Manual page 29

Intellipath series 4g gsm communicator
Table of Contents

Advertisement

PROMPTS
Device Mode
9
(ECP)_
NOTE: In order for the Multi Mode, Remote Access, and Keypad Address programming fields to appear an account
must be created in the AlarmNet Direct website and "Remote Access" must be enabled for the comm device.
In Zone Trigger mode, the options for Multi-Mode are "Enabled" or "Disabled." If enabled, whenever a zone on the
communication device is triggered, a corresponding email message is sent INSTEAD of normal central station
reports. Cover tamper will send email event 8. All communication device system events (such as power loss, low
battery, Telco, etc.) are still sent to AlarmNet.
Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to
events triggering the hardwired zones.
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central
Station reporting of critical events (alarms, troubles, etc.).
UL
Multi-Mode has not been evaluated by UL.
Multi Mode
10
(Disabled)_
Important Information Regarding Primary Account (Questions 11-13)
Account information is provided by the central station administrator.
Primary City ID
11
(??)_
Primary CS ID
12
(???)
Primary Sub ID
13
(????)
Device Address
14
(12)_
UL / ULC
Remote access has not been evaluated by UL or ULC.
Remote Access
15
Y/N
(N)_
4204/
ZONE
OPTIONS
2-4204
TRIG.
• ECP
X
X
• Zone Trig.
• 4204 Emu
• Two 4204s
Important Information Regarding Multi-Mode Options
• Enabled
X
• Disabled
[01-99]
X
X
[01-FE]
X
X
[0001-9999]
X
X
[01-15]
X
[Y], [N]
X
Section 3: Programming the Communicator
DESCRIPTION
Press the [space] key to scroll through the modes of
operation.
Press [ENTER] to select the mode of operation.
IMPORTANT, if ECP device mode is desired, use
Table 3-2 for programming.
Enable if you want all events sent by email to the
user. Disable for normal alarm processing.
Enter the 2-digit primary city ID, 01-99 (decimal).
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
The GSMV4G communicates with the control panel
as a 4204 relay module. Enter the appropriate
address. For VISTA-10P and FA130CP Series
control panels, this must be address 12. For other
control panels, see their Installation and Setup
Guide.
NOTES:
1. The 4204 protocol limits address range to 01-15.
If using 2-4204 mode, the communicator assigns
the second 4204 to the next higher device address
(e.g., if entering address 12 for the first 4204, then
address 13 is automatically assigned to the second
4204 module). Program the control panel
accordingly.
2. The device address(es) must be unique from the
"Keypad Address" entered in Prompt 17 and any
other address used on the control panel.
Press [Y] to allow the end user to access their
system via a website. Availability of this service is
controlled by the dealer via the web-based
programming tool on the AlarmNet Direct website.
3-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gsmvcn4g

Table of Contents