AreaRAE Plus & AreaRAE Pro User's Guide
17.5 Replacing The Sensor Compartment Cover
Before replacing the sensor compartment cover, inspect the large O-ring gasket for damage. If it is
damaged, discard it and use a new one.
1. Place the O-ring gasket in the compartment. (Inspect the O-ring gasket for wear or
damage first. If necessary, replace it.)
2. Press all the sensors firmly in place to ensure they are seated correctly.
3. Set the sensor compartment cover on top of the compartment.
4. Tighten the four screws. Note: Do not overtighten.
17.6 Battery Removal/Replacement
The battery is located in a bay in the lower half of the AreaRAE Plus/Pro's back.
Changing the AreaRAE Plus/Pro battery pack requires a Philips screwdriver. To replace the AreaRAE
Plus/Pro battery:
1. Turn the instrument off.
2. Remove the filter from the front of the instrument.
3. Place the instrument face-down on a soft surface.
4. Remove the four screws that hold the battery.
86