Datalog - Honeywell AreaRAE Plus User Manual

Gas
Hide thumbs Also See for AreaRAE Plus:
Table of Contents

Advertisement

AreaRAE Plus & AreaRAE Pro User's Guide

12.3.4 Datalog

The instrument displays a floppy disk icon to indicate that a datalog is being recorded. The instrument
stores the measured gas concentration for each sensor, date and time for each measurement, Site ID, User
ID, and other parameters. The AreaRAE Plus/Pro memory is sufficient to record six months' worth of
data for 12 sensors and GPS at one-minute intervals, 24/7. All data are retained (even after the unit is
turned off) in non-volatile memory so that they can be downloaded at a later time to a PC.
Clear Datalog
This operation erases all data stored in the datalog. Select "Clear Datalog," and then "Yes."
Note: Once the datalog is cleared, the data cannot be recovered.
Datalog Interval
Intervals are shown in seconds. The default value is 60 seconds. The maximum interval is 3600 seconds,
and the minimum is 1 second.
Sensor Selection
You can choose which sensors' data are included in the datalog. The entire list of installed sensors is
shown, and you can individually select whether their data is included.