DTC P0496: EVAP System High Purge Flow
1. Turn the ignition switch ON (II).
2. Clear the DTC w i t h the HDS.
3. Do the EVAP FUNCTION TEST in the INSPECTION
MENU w i t h the HDS.
Is the result OK ?
YES—Intermittent failure, system is OK at this t i m e .
Check for poor connections or loose terminals at
the FTP sensor, the EVAP canister purge valve, or
the EVAP canister vent shut valve and the PCM. •
N O — G o t o step 4.
4. Turn the ignition switch OFF.
5. Replace the EVAP canister purge valve (see page
11-436).
6. Turn the ignition switch ON (II).
7. Reset the PCM w i t h the HDS.
8. Do the PCM idle learn procedure (see page 11-340).
9. Do the EVAP FUNCTION TEST in the INSPECTION
MENU w i t h the HDS.
Is the result
OK?
YES—Troubleshooting is complete. •
NO—Check for poor connections or loose terminals
at the FTP sensor, the EVAP canister purge valve, or
the EVAP canister vent shut valve and the PCM,
t h e n go to step 1.