Specifications - Honeywell TH8320R1003 Vision Pro 8000 Product Data

Hide thumbs Also See for TH8320R1003 Vision Pro 8000:
Table of Contents

Advertisement

SPECIFICATIONS

Thermostat Description:
Feature
Powering method
• Common wire or battery
• Gas, oil or electric heat with air
System types (up to
4 heat/2 cool heat
conditioning
• Warm air, hot water, high-efficiency
pump and up to 3
heat/2 cool
furnaces, heat pumps, steam and
conventional)
gravity
• Cool only
Changeover
Manual or Auto changeover selectable
System setting
Em Heat-Heat-Off-Cool-Auto
Fan setting
Auto-On-Circ-Follow Schedule
Electrical Ratings:
Terminal
W - O/B
18 to 30 VAC and
750 mVDC
Y (cooling)
18 to 30 VAC
G (fan)
18 to 30 VAC
W2 - Aux 1 (heating)
18 to 30 VAC
W3 - Aux 2 (heating)
18 to 30 VAC
Y2 (cooling)
18 to 30 VAC
A-L/A (Output)
18 to 30 VAC
U1, U1
30 VAC max.
U2, U2
U3, U3
RedLINK Communication:
Frequency: 900 Mhz frequency range
Re-Sync Time: RedLINK devices re-establish communication
within 6 minutes after AC power resumes.
Temperature Setting Range:
Heating: 40 to 90 °F (4.5 to 32 °C).
Cooling: 50 to 99 °F (10 to 37 °C).
Humidification Setting Range:
10% to 60% RH.
Dehumidification Setting Range:
40% to 80% RH.
Humidity Display Range:
0% to 99%.
Cool Indication:
VisionPRO® 8000 with RedLINK™ displays "Cool On" when
the thermostat turns the cooling on.
Heat Indication:
VisionPRO® 8000 with RedLINK™ displays "Heat On" when
the thermostat turns the heating on.
Auxiliary Heat Indication:
VisionPRO® 8000 with RedLINK™ displays "Aux Heat On"
when the thermostat turns the auxiliary heat on.
Description
Voltage
Max. Current
(50/60 Hz)
Rating
1.00A
1.00A
0.50A
0.60A
0.60A
0.60A
1.00A
0.50A
Interstage Differential:
Comfort: The thermostat keeps the indoor temperature within 1
degree of the setpoint (droop less control). The thermostat
turns on stage 2 when the capacity on stage 1 reaches
90%.
When the interstage differential is set to 1.0 or higher, the ther-
mostat stages the equipment based on how far the indoor
temperature is from the setpoint (ISU 303 to 309). See
page 26 for more information.
Clock Accuracy: 1 minute per month at 77 °F (25 °C). ± 2
minutes per month over the operating ambient temperature
range.
Mounting Means:
Thermostat mounts directly on the wall in the living space
using mounting screws and anchors provided. Fits a hori-
zontal 2 x 4 in. junction box.
Equipment Interface Module (EIM) mounts on HVAC equip-
ment or on a wall in the equipment room.
4-15/16 (126)
3-5/16 (84)
Fig. 1. Dimensions of thermostat in in. (mm).
5-3/4
(146)
1-1/2
(38)
Fig. 2. Dimensions of VisionPRO cover plate in in. (mm).
3
®
VISIONPRO
8000 WITH REDLINK™
4-5/8
(118)
1-1/8 (29)
M34521
6-5/32
(156)
25/32
(20)
M34258
68-0312—01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th8321r1001 vision pro 8000Th8110r1008 vision pro 8000