Overview

Before you start

Read the entire document

  • Installation must be carried out by a certified electrician and must comply with national and local electrical codes.
  • To prevent severe shock or electrocution, always cut the power at the service panel before working with wiring.
  • Use this thermostat for resistive loads only.
  • Do NOT install the thermostat in an area where it can be exposed to water or rain.
  • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes.
  • For a new installation, choose a location about 1.5 m (5 ft.) above the floor.
  • Install the thermostat on an inside wall facing the heating system.
  • Install the thermostat onto an electrical box.
  • Use special CO/ALR solderless connectors if you connect the thermostat to aluminum wires.
  • Keep the thermostat's top and bottom air vents (openings) clean and unobstructed at all times.

About your thermostat

Honeywell Home's TL8130A1005 thermostat can be connected to an electric heater to control the room temperature.

Supplied Parts

  • One (1) thermostat
  • Two (2) mounting screws
  • Four (4) solderless connectors for copper wires

Controls

Controls Overview* Place at Standby to cut power to the heater (e.g., in the summer). This will not affect the time and temperature settings.
** When the backlight button or either of the buttons is pressed, the display illuminates for 12 seconds.

Display

Display Overview
* The thermostat normally displays the actual (measured) temperature. To view the setpoint temperature, briefly press either of the buttons. The setpoint will appear for 5 seconds. To change the setpoint temperature, press one of the buttons until the desired temperature is displayed. To scroll faster, press and hold the button.

Installation

Installing the thermostat

Installing the thermostat

  1. Turn the heating system off at the main electrical panel.
  2. Loosen the bottom screw and remove the thermostat faceplate from its wallplate. (The screw cannot be completely removed.)
  3. Connect the thermostat to the load and to the power supply.
  4. Install the wallplate to the electrical box using the provided screws.
  5. If necessary, set the configuration switches on the back of the faceplate.
  6. Install the faceplate back on the wallplate and tighten the screw. If there is a sticker on the screen, peel it off.
  7. You can now return power to the heating system at the main electrical panel.

Wiring diagram

NOTE: Connect the wires using the provided solderless connectors for copper wires.
Wiring diagram

Setting the configuration switches

Configuration switches are on the back of the faceplate.

# Configurations Up Down
1 Display format °F / 12 h °C / 24 h
2 Early Start 1 Enable Disable
3 Not used
  1. Early Start is used in Automatic mode only. When Early Start is enabled (on), the thermostat determines when to start heating so the Comfort temperature is attained at the beginning of periods 1 and 3. When Early Start is disabled (off), heating starts only at the beginning of periods 1 and 3; thus there is a delay before the Comfort temperature is reached.

Setup

Time and day

To set the clock and the day:

  1. Press the Hour button to set the hour.
  2. Press the Min button to set the minutes.
  3. Press the Day button to set the day.
  4. Press the Mode/Ret button to return the thermostat to normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Daylight Saving Time

When the Daylight Saving Time function is enabled (On), the thermostat automatically switches to Daylight Saving Time on the second Sunday of March and to normal time on the first Sunday of November.
NOTE: The Daylight Saving Time function is disabled (default setting) when the clock loses its setting.
To set the Daylight Saving Time function and to set the date:

  1. Press the Day button (3 seconds) until DLS appears on the screen.
  2. Press either of the buttons to toggle between On (enabled) and Off (disabled).
  3. Press the Day button briefly. The year setting is displayed.
  4. Press either of the buttons to set the current year.
  5. Press the Day button briefly. The month setting is displayed.
  6. Press either of the buttons to set the current month.
  7. Press the Day button briefly. The date setting is displayed.
  8. Press either of the buttons to set the current date.
  9. Press the Mode/Ret button to return the thermostat to normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Preset temperatures

The thermostat has 3 preset temperatures. Their default settings are shown in the following table.

Preset temperature Intended use Icon Default setting
Comfort When at home 21.0°C (70°F)
Economy When asleep or away from home 16.5°C (62°F)
Vacation During prolonged absence 10.0°C (50°F)

To use a preset temperature:
Briefly press the appropriate preset temperature button (, or ). The preset temperature will become the current setpoint and its icon will appear on the screen.

To modify a preset temperature:

  1. Press one of the buttons to display the desired temperature.
  2. Press and hold the appropriate preset temperature button ( , or ) until its icon is displayed.

Default schedule

The schedule consists of 4 periods per day, which represents a typical work day. The Comfort () temperature is automatically used in Periods 1 and 3 and the Economy () preset temperature in Periods 2 and 4. You can program the thermostat to skip (cancel) the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend.
NOTE: If you wish to use only 2 periods, use the following combinations: "1 and 4" or "2 and 3". Early Start will not work with any other combinations. You can have a different program every day; i.e., each period can start at a different time every day. The thermostat has been programmed with the following schedule.

Period Description Setting MO TU WE TH FR SA SU
Wake Comfort 6:00 AM 6:00 AM 6:00 AM 6:00 AM 6:00 AM 6:00 AM 6:00 AM
Leave Economy 8:00 AM 8:00 AM 8:00 AM 8:00 AM 8:00 AM --:-- --:--
Return Comfort 6:00 PM 6:00 PM 6:00 PM 6:00 PM 6:00 PM --:-- --:--
Sleep Economy 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM

Modifying the schedule

  1. Press Pgm. Period 1 for Monday is displayed.
  2. To program another period, press Pgm to display that period.
  3. To program another day, press Day to display that day (hold for 3 seconds to select the entire week).
  4. Press Hour and Min to set the period start time, or press Clear to skip (cancel) the period (--:-- will be displayed).
  5. Repeat steps 2 to 4 to program another period.
  6. Press Mode/Ret to return the thermostat to normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Operation

Running the schedule (Automatic mode)

In Automatic mode, the thermostat follows the programmed schedule. To place the thermostat in this mode, press Mode/Ret until displayed.

Temporary override of schedule

If you modify the setpoint temperature (by pressing the , or button) when the thermostat is in Automatic mode, the new temperature will be used until the beginning of the next period. flashes during the temporary override. You can cancel the temporary override by pressing Mode/Ret.

Permanent override (Manual mode)

To place the thermostat in Manual mode, press Mode/Ret to display on the screen. In this mode, the thermostat does not follow the programmed schedule. Press the , or button to set the temperature.

Error messages

The measured temperature is below the display range. Heating is activated.
The measured temperature is above the display range. Heating is deactivated.
Verify the thermostat connection and sensor connection.

Technical specifications

Power supply: 240/208 VAC, 50/60 Hz
Maximum load: 16.7 A (4000 W @ 240 VAC) (3470 W @ 208 VAC)
Heating cycle: 15 minutes
Setpoint range: 5°C to 30°C (40°F to 86°F)
Display range: 0°C to 70°C (32°F to 158°F)
Resolution: 0.5°C (1°F)
Data protection: In the event of a power failure, most settings are saved. However the time and Daylight Saving Time must be set if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power failure.

Customer assistance

If you have any questions about the operation of your thermostat, please go to www.honeywellhome.com.
© 2021 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Honeywell TL8130A1005 - 7-Day Programmable Thermostat Manual

Advertisement

Need Assistance?

Do you have a question about the TL8130A1005 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents