Parameterization Of Infeed - Siemens SINUMERIK 840D sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

8.5.1

Parameterization of infeed

Introduction
You want to configure/parameterize the Active Line Module of your SINAMICS> You have
selected the menu "Commissioning > Drive systems > Infeed". You are in the following
menu:
Figure 8-18
Operating sequences
1. If multiple infeeds are present, select the infeed with "Infeed+/Infeed-".
2. Press the vertical softkey "Change".
Figure 8-19
IBN CNC: NCK, PLC, drive
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
Menu "Infeed > Configuration"
The system detects that the infeed has not been commissioned and that a commissioning
is required (see above figure).
The commissioning is performed with the "Change" vertical softkey.
Menu "Infeeds > Configuration" "Names" (Change)
Commissioning SINAMICS drives
8.5 Commissioning using a drive wizard
75