Licensing
14.9 Assigning via Automation License Manager
Statements
AddressParameter
[
ADDRESS0 =
ADDRESS1 =
ADDRESS2 =
ADDRESS3 =
ADDRESS4 =
ADDRESS5 =
ADDRESS6 =
ADDRESS7 =
Multiple SINUMERIK control systems
If you require communication with multiple SINUMERIK control systems you must create a
section
AddressParameter
[
control system with the relevant IP address.
In the [ GLOBAL ] section, you must specify the section name for the SINUMERIK control
system, e.g. [ 840D_001 ], with which communication should occur once the Automation
License Manager has booted.
NOTICE
Editing the IP address
The IP address specified in the user-specific initialization file MMC.INI influences not only
the Automation License Manager but also all other applications installed on the same
computer (PC/PG) that use HMI basic software (e.g. HMI Advanced).
To apply the change to the active IP address, you must close all active applications using
HMI basic software (e.g. HMI Advanced). Once you have closed all applications, restart the
computer to activate the new IP address.
Requirements
The following conditions must be fulfilled:
● The HMI basic software is installed on the computer (PC/PG) on which the Automation
● The IP addresses of the SINUMERIK control systems with which the Automation License
Procedure: Creating parameters for the first time
Perform the following actions when creating user-specific communication parameters for the
first time:
1. Create the text file:
<installation drive>:\Siemens\Sinumerik\HMI-Advanced\user\MMC.INI if it does not
already exist.
2. Open the file MMC.INI with a text editor.
278
]
IP address
, LINE=10,NAME=/NC, SAP=030d, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10,NAME=/PLC, SAP=0201, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10, NAME=/DRIVE0, SAP=0900, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10, NAME=/DRIVE1, SAP=0a00, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10, NAME=/DRIVE2, SAP=0b00, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10, NAME=/DRIVE3, SAP=0c00, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10, NAME=/DRIVE4, SAP=0d00, PROFILE=CLT1__CP_L4_INT
IP address
, LINE=10, NAME=/DRIVE5, SAP=0e00, PROFILE=CLT1__CP_L4_INT
] with a unique name e.g. [ 840D_001 ], [ 840D_002 ], etc. for each
License Manager is running.
Manager must communicate are known.