● IMMEDIATE (so)
Protection levels
Access level 4 (keyswitch position 3) or more is required to display machine data.
To start up the system the appropriate access level must generally be enabled by entering
the password "EVENING".
Unit
The unit refers to the standard setting of the machine data:
SCALING_FACTOR_USER_DEF_MASK,
SCALING_FACTOR_USER_DEF and
SCALING_SYSTEM IS METRIC = 1.
If the machine data is not based on an engineering unit, then the field is marked with "-".
Default value
The machine data/setting data is preset to this value.
Note
Inputs via HMI are limited to ten digits plus comma and sign.
Value range (minimum and maximum)
Specifies the input limits. If no range of values is specified, the data type determines the
input limits and the field is marked with "∗∗∗".
IBN CNC: NCK, PLC, drive
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
– After entry of value
Note
Unlike machine data, changes to setting data always become effective immediately.
Fundamentals
15.5 Machine and setting data
313