Boot Completed - Siemens SINUMERIK 804D sl Commissioning Manual

Cnc part 1 nck, plc, drive
Table of Contents

Advertisement

5.3

Boot completed

Introduction
After an error-free boot of the NCU, it displays the following:
• Number "6" and a flashing point
• LED RUN illuminates GREEN continuously
To resume the startup on the user interface of the HMI, the following operator input
sequence steps are necessary:
Operator input sequence steps for entry into startup
1. Press <Menu Select>
2. Press "Commissioning".
3. Press "Password...".
4. Press "Set password".
5. Enter the manufacturer's password "SUNRISE".
6. Press "OK".
Figure 5-2
Run-up has been completed.
In the following step commissioning of the PLC is done with the SIMATIC Manager.
See also
Carry out NCK reset (Page 59)
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0
The following figure displays the user interface which is used during commissioning of the
PLC to initiate a "NCK reset".
"Commissioning" menu
, or the <F10> key on the PG/PC.
Power on and boot up
5.3 Boot completed