Integrating Pg/Pc Into Netpro - Siemens SINUMERIK 804D sl Commissioning Manual

Cnc part 1 nck, plc, drive
Table of Contents

Advertisement

13.4.1

Integrating PG/PC into NetPro

Introduction
To enable the communication between PG/PC <-> HMI via Ethernet, the PC/PG is to be
included in the network configuration of the system.
To integrate the PG/PC, proceed from the following starting situation in the
SIMATIC Manager.
You are in the HW config in the created project "PLC-Erst-IBN 840D sl" (see figure below).
Figure 13-7
Operator input sequence steps - Integrating PG/PC into NetPro
Using the following operator input sequence steps, you can integrate a PC/PG into NetPro:
1. Click on the "NetPro" button (see figure above).
2. From the catalog under "Stations", insert the PG/PC via Drag&Drop into the network
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0
HW config project "PLC-Erst-IBN 840D sl"
configuration (see figure below).
13.4 Integrating PG/PC into the network (NetPro)